Manometer
MANOMETERS are offered in inclined
and vertical style for highly accurate laboratory or general industrial
service, for measurement of low range gas and air pressures, positive,
negative or differential. To assure the accuracy required in instrument
of this type, all machining of bores and wells is of the highest
precision.
Design
- 1 thick acrylic body is a
solid blocm, virtually unbreakable, stable and free of the danger
of distortion
- Drilled bores accurate to 002 is
stable of bends or crooks and does not need recaliberation because
of distortion.
- Selected gage oil with high wetability
characteristics for a consistent well shaped meniscus for most
accurate reading.
- Adjustable reflective polished aluminium
scales with thumbscrew locking for easy zeroing.
- Parallax free reading for maximum
accuracy and consistency.
- Leaving adjustment for inclined
style is achieved by simple loosening a locking thumbscrew on
the side or bottom of the gauge, adjusting with reference to the
integral sensitive ground bubble level and retighting.
Tel: 022 24451888/ 24466019
Telefax: 022 24466019
Air Atomizing Spray
Nozzle
THE Air Atomizing Spray Nozzle is a
unique two-substance nozzle, which finds its application in tablet
coating, humidifying air and products, tracking, light and heavy
oil firing, spray coating, drying, air and gas cooling, etching
plants and residue combustion and where very large and high viscous
quantities of liquids and pastes have to be turned to mists or fine
atomized.
Efficiently designed to reduce compressed
air consumption, it works under an atomizing pressure of 0.3 kg/cms
upwards. This two substance nozzle guarantees a large surface coverage
at a minimum of energy. The Spray angle in a flat fan can be varied
from 10 degree to a maximum of 90 degree.
Highly
atomized sprays can be obtained at a relatively low flow rate. The
flow rate in these nozzles can be varied from 0.05 LPM to 25.0 LPM.
The liquid can be fed under principles of gravity, suction or by
pressure. A flat fan is designed with a fine adjustment screw for
adjusting the spray angle from 10 degree to maximum of 90 degree,
keeping the flow rate constant.
In a flat fan the mixing takes place
externally. Clogging of the liquid orifice is avoided by providing
a automatic cleaning needle within the nozzle. These nozzles provide
an independent flow of liquid atomizing air and fan air and both
liquid and air flow rates can be controlled allowing accurate metering.
The precise design of an inbuilt cleaning
needle facilitates in quick cleaning of the nozzle outlet during
an operation. This pneumatically controlled needle has an extra
compressed air inlet, whereby on switching off this compressed air
supply, the needle closes, automatically and abruptly the liquid
outlet, thereby avoiding any post dropping.
All individual components are available
as spare parts ie. nozzle bodies, liquid inserts and air caps. The
precise manufacturing of replacement parts ensures interchangeability
and same spray performance with the nozzles and air cap settings.
These nozzles are available in desirable
end connections from 1/8 BSP/NPT (male/female) connection
to 1/2 BSP/NPT (male/female), and mainly manufactured out
of SS 304 and SS 316 for possible hygiene purpose, but on request
could be supplied with any other machinable material.
Tel: 91 22 4223288/ 4224888
Fax: 91-22-4363531/ 4223288
Email: http://www.indiavibescom/sidharth/.
Siltabs
Slittng: Siltabs coated roll
are slit on sophisticated slitter with a web cleaner ensuring each
spool dust free and tightly wound films with adequate slipping property.
The Siltab coated films are available in all slitting
width of any size as per customers requirements.
Packaging:
Each Siltabs spool are wrapped in black air bubbles films for preventing
it from yellowing and brittleness. Maximum care is taken to prevent
it from any damage during transit. Each spool and box are labelled
with complete identification about the product and are send to the
customer only after QC final approval.
Used and Storage: It is recommended
to use PVDC coated film within 6 months of manufacturing for best
results. It should be stored in their original packing at temperature
between 15 to 30o C until ready for use. Protect it from direct
sunlight. Never process cold material.
Advantages of PVDC coated PVC Film:
PVDC coated PVC films offer excellent barrier properties so as to
protect tablets and capsules from:
- Moisture and water vapour
- Gases
- Oils
- Fats and aromas etc.
Tel: 307 1996/ 309 2626
Fax: 3087980
Email: schwabeincoat@netscape.net
Agitated Pressure
Nutsche Filter Dryer
THIS
is a Combination of filter and dryer with in single equipment to
achieve economy in process and energy thereby improving profitability.
Speciality of this equipment is that it is provided with mechanical
seal and is working totally with hydraulic system. The equipment
can be operated either under pressure or under vacuum. The equipment
is provided with a stirrer mechanism. The stirrer blades are designed
such that it stirs the materials in filtration and washing operation
as well as it discharges material automatically through specially
designed, hydraulically operated, side discharge valve, when it
rotates in forward direction.
The backward direction of stirrer squeezes
the cake thereby ensuring the maximum extraction of moisture from
cake. Spray arrangement is provided inside the equipment to spray
the washing liquid. Jacket on shell is provided for heating process.
A heating chamber is also provided below filter plate to heat the
cake from bottom. A heating chamber is also provided below filter
plate to heat the cake from bottom. Flat detachable bottom is provided
without cumbersome bolting system. Detachable bottom is operated
by hydraulic cylinders operated by hydraulic powerpack and seals
the equipment automatically for no leakage.
Salient features
- Designed and manufactured to suit
critical hygienic conditions of pharma and food industries. (GMP
Model)
- Detachable bottom is operated by
hydraulic cylinders and held tightly with zero leakage. No bolting
requirement.
- Offered in various materials of
construction, like stainless steel, carbon steel, rubber lined
carbon steel and lead lined carbon steel.
- Offered in a wide range of filtration
area capacities upto 15.5 sq. meters. 4.5 mt. dia
- The filtration process is very fast.
- Significant squeezing of filter
cake is possible, thereby resulting in considerably lower residual
moisture in the cake, resulting in reduction in energy requirement
for drying of filter cake by upto 40 per cent depending on cake
characteristics.
- Method of operation is totally enclosed,
neat and hygienic. These conditions are excellent for solvent
recovery, handling to toxic and hazardous materials without human
intervention.
- Enable easy, non manual and automatic
cake/ solid discharge. Scrapper blade is provided to scrap the
material which may stay on shell.
- The unit is designed with minimum
maintenance features
- Several GMP models are working in
reputed pharmaceutical and chemical companies.
Tel: 91 22 5165971/ 0251-871511
Fax: 91 22 5162744/ 0251-871683
Email: bifriends@vsnl.net
Rotocone Vacuum
Filter Dryer System (RCVFD)
THE
Rotocone Vacuum Filter Dryer System (RCVFD) has been uniquely designed
and manufactured with lump breaker provision. It works as filter
as well as dryer very effectively. It is modified version of Rotocone
Vacuum Dryer. One half part of the equipment is conical which is
provided with external jacket for heating and other half part acts
as filter which is provided with filter media and cake washing arrangement.
Choppers can be provided in dryer section for specific requirement
of customers.
Salient Features:
- Single equipment for filtration
and drying for cake and powders. So space and labour is saved.
Handling is reduced
- Totally sealed and protected from
contamination
- Fast filtration and drying as vacuum
is employed. So energy is saved.
- Quick loading and unloading. So
time is saved.
- Provision of sampling nozzle without
breaking vacuum.
- Compact design gives excellent appearance
to equipment
- Designed and manufactured to sunit
critical hygienic conditions of pharma and food industries. (Confirming
to GMP standards)
- The unit is completely air tight,
hence no pollution in environment.
- Self emptying with minimum product
hold up.
- Useful for full solvent recovery.
- Dust free operation.
Tel: 91 22 5165971/ 0251-871511
Fax: 91 22 5162744/ 0251-871683
Email: bifriends@vsnl.net
|